HANNA HI1053B Konik Uçlu ve BNC Konnektörlü pH Elektrodu

HANNA HI1053B Konik Uçlu ve BNC Konnektörlü pH Elektrodu

Marka
Stok Kodu
HANNA HI1053B
İndirimli Fiyat
293,50 USD + KDV
Havale
11.889,30 ₺ (%2,00 havale indirimi)
*12.131,94 ₺ den başlayan taksitlerle!
%10 İndirimli
12.131,94 ₺
13.479,93 ₺
; float: left; width: 150px; clear: both;" />

Refillable

The HI1053B is a refillable probe. Since it is a double junction pH electrode, the fill solution is the HI7082 3.5M KCl. This solution does not contain any silver which is necessary for single junction electrode fill solutions.

 

BNC

BNC Connector

The HI1053B uses a BNC connector. This type of connector is universal in that it can be used on any pH meter that has the female BNC probe input. Other type of connectors include DIN, screw type, T-type, and 3.5mm to name a few. These types of connectors tend to be proprietary for a particular type of meter and are not interchangeable.


 

single vs double junction

Conventional electrodes are normally single junction. As depicted by the figure above, these electrodes have only a single junction between the internal refernce wire and the external solution. Under adverse conditions, such as high pressure, high temperature, highly acidic or alkaline solutions, the positive flow of the electrolyte through the junction is often reversed resulting in the ingress of sample solution into the reference compartment. If this is left unchecked, the reference electrode can become contaminated, leading to complete electrode failure. Another potential problem with single junction electrodes is the clogging of the junction due to silver chloride (AgCl) precipitation. Silver can be easily precipitate in samples that contain Tris buffer, sulfides or heavy metals. When the electrolyte solution makes contact with the sample, some AgCl will precipitate on the external face of the junction. The result is drifty readings obtained from the sensor.

Hanna’s double junction system, as the name implies, has two junctions, only one of which is in contact with the sample as shown in the figure. Under adverse conditions, the same tendency of sample ingress is evident. However, as the reference electrode system is separated physically from the intermediate electrolyte area, the contamination of the electrode is minimized. The likelihood of clogging of the junction is also reduced with a double junction electrode since the outer reference cell uses a fill solution that is "silver-free”. Since there is no silver present, there is no precipitate forming to clog the junction.

 


Body Material glass
Reference double, Ag/AgCl
Junction / Flow Rate ceramic, triple / 40-50 μL/h
Electrolyte 3.5M KCl
Range pH: 0 to 12
Max Pressure 0.1 bar
Tip Shape conic (12 x 12 mm)
Diameter 12 mm
Body Length / Overall Length 120 mm / 175.5 mm
Recommended Operating Temperature -5 to 70°C (23 to 158°F)
Temperature Sensor no
Matching Pin no
Amplifier no
Digital no
Cable coaxial; 1 m (3.3’)
Connection BNC
Applications emulsions, fats and creams, low conductivity solutions, potable water, semi-solid products, soil samples
Warranty 6 months

HANNA HI1053B Konik Uçlu ve BNC Konnektörlü pH Elektrodu Problar & Elektrotlar kategorisinde bulunan HANNA markalı HANNA HI1053B Konik Uçlu ve BNC Konnektörlü pH Elektrodu ürününü, ister tek çekim kredi kartı ile, ister 9 taksite kadar, ister havale/EFT ile satın alabilirsiniz. | HANNA HI1053B
HANNA HI1053B Konik Uçlu ve BNC Konnektörlü pH Elektrodu